Direct Dental Customer Service

1-866-284-9690

Oral Dental Products Team

oral.dental@exac.com

Frequently Asked Questions

All Regenaform® and Regenafil® pastes:

If we don’t use all of the paste in a syringe at once, can we use it later in the case?

Yes. Place the cap on the syringe and place it in sterile warm water at 43° to 49°C (110° to 120°F).

Can unused portions of the pastes be reused in another surgery?

No. Individual paste packages are for single patient use only.

Can over-warming the paste damage it?

As with all osteobiologics, exposing the paste directly to temperatures in excess of 54°C (129°F) will denature some of the proteins and destroy the product.

What if the paste stops coming out of the syringe or stops molding easily mid-use?

The paste may have cooled. Recap the syringe (if not packaged in a syringe, place in a watertight sterile bag) and warm for approximately five minutes (or until paste flows or shapes easily) before reusing.

Are Regenafil and Regenaform pastes tested for osteoinductivity?

Yes. Every lot of demineralized bone material used in Regenafil paste is implanted in vivo in an athymic nude rat to test its osteoinductive potential. Only lots that pass this practical quality control test are considered osteoinductive and are processed into Regenafil and Regenaform paste products.